How Did Benson & Forsyth Do This?
- This topic has 33 replies, 11 voices, and was last updated 17 years, 2 months ago by
Anonymous.
- AuthorPosts
- July 7, 2009 at 1:21 pm #710633
mulp
ParticipantI would appreciate some informed opinions on this issue:
Benson & Forsyth’s National Gallery Extension contains two public staircases that do not meet the guidance set out in TGD Part k: Length of Flights: 1.1.11 There should not be more than sixteen risers in any one flight.
The flight at the rear of the main hall has 20 risers and the uppermost flight at the rear of the extension has 19 risers. They are straight flights without any half landings.
I don’t consider these stairs to be in any way unsafe, but the TGD evidently does.
Compliance with the TGD demonstrates compliance with the Regulation, but the designer is free to demonstrate other methods of compliance.
I am designing an extension to a protected structure in which I want to have a straight fllght with 18 risers. A lift is to be located adjacent to the stair. I don’t consider a stair with 18 risers to be any more unsafe than one with 16 and believe that the elderly or infirm would opt for the lift. My main concern is public liability.Can anyone suggest how B&F would have demonstrated compliance with Part K in the Gallery?
Would you, as a designer, be prepared to certify a similar stair as compliant?(Note: I can’t see any way that the ‘protected’ status of the main gallery is relevant in relation to a relaxation, as the works are entirely within the new extension).
Thanks.
July 7, 2009 at 1:52 pm #808166Paul Clerkin
KeymasterThere is a central handrail since this photo was taken – was added very soon after opening.
at least I think there is…. fuzzy today
July 7, 2009 at 1:57 pm #808167Anonymous
InactiveCentral handrail has been added with some pot plants, I find the ‘gaps’ in the walkway even more worrying
July 7, 2009 at 3:13 pm #808168Anonymous
Inactivein the south pole you can do 18 steps! if you want more here you get a dispensation for a performance based provision… you might have to pay a consultant! normally the regulation is vague (the short bit at the front) and the rest is should… All from the same old British regs but remixed. I’m so over trying to interpret standards and pay consultants everyone reads them differently… And nobody does any inspections in Ireland. The fire regulations are OTT normally sprinklers can make the impossible possible… not in Ireland where the water is free…
I guess its a bit like a train platform with more than a metre drop… you should have a handrail and balustrade or some steps so you don’t fall on the tracks while your waiting…
I admire the Irish reg’s for being so simple and un-bible like (forgot about part b)
http://www.flickr.com/photos/44535691@N00/389436674/sizes/l/
why don’t you just go to the source and call them? and let us know
everyone so worried about not getting sued these days there is not much room for architecture…
July 7, 2009 at 3:38 pm #808169Anonymous
Inactivecompliance on building regulations is a matter of opinion.
Whose opinion matters?
A building control officers opinion is no more valid than a street buskers opinion. At the end of the day the only opinion that matters is the judges opinion in a case where someone falls and gets injured, and an action is taken.
July 7, 2009 at 4:02 pm #808170Anonymous
InactiveThe latest British Standard (BS8300-2009_Design of buildings and their approaches to meet the needs of disabled people: Section 5.9.3 Rise of a flight) proposes ‘no flight on an external stepped access route should contain more than 20 risers and, as far as possible, the numbers of risers in successive flights should be uniform’. This also applies to internal stairs.
July 7, 2009 at 4:30 pm #808171Anonymous
Inactivemost fire officers will tak ethe view that the TGDs supercedes any BS…
July 7, 2009 at 5:00 pm #808172Anonymous
Inactive@henno wrote:
most fire officers will tak ethe view that the TGDs supercedes any BS…
My understanding would be that fire officers refer primarily to TGD Part B which does not govern the maximum no. of risers.
July 7, 2009 at 5:38 pm #808173Anonymous
Inactive@Copo wrote:
My understanding would be that fire officers refer primarily to TGD Part B which does not govern the maximum no. of risers.
primarily Part B yes, but not exclusively…
they will refer to part k for stairs etc… ..
part j for heat producing appliances….
part m for disabled access…etc
July 7, 2009 at 8:13 pm #808174Anonymous
InactiveIn Ireland we rely on self certification by Design Professionals and Builders (when requested) on completion to give an “Opinion” on compliance with the Building Regulations.
A Fire Safety application and approval procedure is uniquely required prior to commencement, but only to approve the design.
In some other countries approval of the design, to validate compliance with all Building Regulations, is given before construction is allowed to commence. Furthermore, local authority inspections take place during the build period to monitor variances between the lodged documents and what is actually built, and to keep an eye on the build process.
The problem with this method is that it is costly to set up and operate, and is open to corruption.
The problem with the Irish method is that too many things, outside Part B, slip through unchecked.
Finally, 16,18 or 20 steps without a landing is a subjective view of what is safe but has the backing of Codes.July 8, 2009 at 6:28 am #808175Anonymous
Inactivehere’s another one for you.. what hurts more assuming same going?
falling 3520mm down 16 stairs at 220mm
falling 3300mm down 20 stairs at 165mm
falling 3135mm down 19 stairs at 165mmHenno is saying 16 stairs or 12 considering its an place of assembly?
I would take the 20 stairs anyday;)1.1.12 In places of assembly to which large
numbers of people have resort, there should be no
more than two consecutive flights each having a
maximum of twelve risers, without a change in
direction of at least 30° between flights (see
Diagram 3).Sub-section 1.1
Stairways and Ladders
1.1.1 Paragraphs 1.1.2 to 1.1.20 give some
guidance on good practice insofar as it relates to
non-complex buildings of normal design and
construction.millennium what about 20stairs = 4400@220mm
or 26 stairs = 4290@165mm?26 stairs ok?
July 8, 2009 at 9:28 am #808176Anonymous
Inactive@missarchi wrote:
here’s another one for you.. what hurts more assuming same going?
falling 3520mm down 16 stairs at 220mm
falling 3300mm down 20 stairs at 165mm
falling 3135mm down 19 stairs at 165mmHenno is saying 16 stairs or 12 considering its an place of assembly?
I would take the 20 stairs anyday;)I wondered what the intent of the limitation to 16 risers was.
Was it regard to the elderly or infirm, to allow them a resting point?
(If you have an adjacent lift is the requirement negated?)To introduce a landing in longer stairs to break a fall?
(missarchi’s point is a good one in that regard).or, as I suspect,
Is it mainly to provide a landing as resting point when two or three persons are carrying a wheelchair user down during an evacuation (when the lift can/may not be used)?An evacuation chair is conspicuously located at the top of the rear, 19-riser flight in the gallery. Would the provision of this equipment demonstrate an alternative means of compliance?
The revised BS8300-2009 (Design of buildings and their approaches to meet the needs of disabled people) would seem very strange if it has increased this limit up to 20 risers. That whole document gets a slating from this reviewer: “Sleepwalking into Problems ?”
Just read that BS 8300-2009 does indeed permit max of 20 risers, describing how landings themselves can create problems for users such as the visually impaired.
July 8, 2009 at 9:52 am #808177Anonymous
Inactive@missarchi wrote:
here’s another one for you.. what hurts more assuming same going?
falling 3520mm down 16 stairs at 220mm
falling 3300mm down 20 stairs at 165mm
falling 3135mm down 19 stairs at 165mmHenno is saying 16 stairs or 12 considering its an place of assembly?
I would take the 20 stairs anyday;)i dont know what you mean… :confused:
there are clear regulations as to the goings and risers based on the use of the building, you cant just pick and choose based on the number of steps….
July 8, 2009 at 9:56 am #808178Anonymous
Inactive@Copo wrote:
The latest British Standard (BS8300-2009_Design of buildings and their approaches to meet the needs of disabled people: Section 5.9.3 Rise of a flight) proposes ‘no flight on an external stepped access route should contain more than 20 risers and, as far as possible, the numbers of risers in successive flights should be uniform’. This also applies to internal stairs.
when I saw this I was convinced it was a typo as I couldn’t believe a jump from 12 risers in BS8300-2001 to 20 now. I’ll stick to the TGD Part K unless I’m in real trouble
July 8, 2009 at 11:05 am #808179Anonymous
Inactive@henno wrote:
i dont know what you mean… :confused:
there are clear regulations as to the goings and risers based on the use of the building, you cant just pick and choose based on the number of steps….
I don’t think they are regulations…
I assume the main issue the the judge will look at is “the regulation”:Stairways, ladders and ramps. K1 Stairways, ladders and ramps shall be such as to afford safe passage for the users of a building.
Protection from falling. K2 In a building, the sides of every floor and balcony and every part of a roof to which people normally have access shall be guarded to
protect users from the risk of falling therefrom.Vehicle ramps, floors and roofs. K3 In a building, the sides of every vehicle ramp and every floor and roof to which vehicles have access shall be guarded against the risk
of vehicles falling therefrom.Application of this Part. K4 The requirements of this Part apply to stairways, ladders and
ramps which form part of the structure of a building.then
The Guidance
The materials, methods of construction, standards and
other specifications (including technical specifications)
which are referred to in this document are those which
are likely to be suitable for the purposes of the
Regulations. Where works are carried out in accordance
with the guidance in this document, this will, prima facie,
indicate compliance with Part K of the Second Schedule to
the Building Regulations. However, the adoption of an
approach other than that outlined in the guidance is not
precluded provided that the relevant requirements of the
Regulations are complied with. Those involved in the
design and construction of a building may be required by
the relevant building control authority to provide such
evidence as is necessary to establish that the requirements
of the Building Regulations are being complied with.I would always follow the guidance where possible…
I mean just think of all those tube trains with disabled fire exits
how many people die from alcohol a year? car crashes? You can do all you want to comply with part B only for someone to disconnect a smoke alarm…
or fire bomb a house or make an insurance claim. Next thing they will recommend you wear a jet pack before you enter a building… and have skylights that you can launch out of
flying fox’s with wheel chair harness’s and escape slides…reading this
People with disabilities have a right, recognized in international law after 3rd May 2008, to equal opportunity and non-discrimination in matters of building fire safety, protection and evacuation. A minimum response to Article 11 (Situations of Risk) in the 2006 United Nations Convention on the Rights of Persons with Disabilities is required, therefore, from fire regulators and code writers. Such a response is absent in British Standard BS 9999:2008.
we may as well have world war three and start fresh.
if your really worried about fire go and live in NORADThere are also disabled architectural styles that have a right to be recognized…;)
henno you saying they should not of built this or let millions of people use it each year?
There is another one in D8
http://www.flickr.com/photos/birispaul/3604129900/July 8, 2009 at 11:23 am #808180Anonymous
Inactivemissarchi…
the point i was making, in response to your post, was that your comparison of a 20 riser stair at 165mm and a 16 riser stair at 220mm is moot because there are regulations which will dictate the rise measurement.
it is disingenuous to compare both of these because a 220mm rise should not exist in a public build… so the question should have been “would i prefer to to fall 16 steps in 165 or 20 steps in 165″… kinda speaks for itself really….
there are regulations… table 1 part k… max rise for a public stair 180mm … optimum 150mm
If you choose not to implement the suggested compliance method in the TGDs, you’d need to be able to argue strongly as to why you did not comply…as to whether the should have not built it…. i would say that it shows a lack of design skills not to be able to design a park K compliant stairwell into the building….
July 8, 2009 at 11:52 am #808181Anonymous
Inactive@henno wrote:
missarchi…
If you choose not to implement the suggested compliance method in the TGDs, you’d need to be able to argue strongly as to why you did not comply…
as to whether the should have not built it…. i would say that it shows a lack of design skills not to be able to design a park K compliant stairwell into the building….
So, to get things back on track, in the example of B&F in the NATIONAL GALLERY, was there a ‘Lack of Design Skills’ or did they make a conscious design decision not to make two of their most prominent staircases non Part K compliant?
Does anyone have an opinion of what the strong argument as to why they did not need to comply with the TGD might have been?P.S. The Sagrada Familia did predate TGD Part K, didn’t it?
July 8, 2009 at 11:53 am #808182Anonymous
Inactive@henno wrote:
missarchi…
agreed I was talking about private but what about public…
150mm x 16 rise =2400mm 19 is possible? = 2850
180mm x 16 rise =2880mmso gaudi should should never have been allow to build the Sagrada familia?
You still have not answered the place of assembly question? 12 rises only?mulp just call them!
July 8, 2009 at 12:13 pm #808183Anonymous
InactiveI knew this had been brought up before
https://archiseek.com/content/showthread.php?t=3690
this is also relevant
http://historical-debates.oireachtas.ie/D/0620/D.0620.200605300173.html
July 8, 2009 at 12:53 pm #808184Anonymous
Inactive“best practice in planning and development for the last 50 years”
carpark…
I’m surprised they don’t have bigger fish to fry… - AuthorPosts